Daewoo DVN-8100N Instruction Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 125
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
The
pitch
feedback
potentiometer
and its
driving
sprocket
gear
are
contained
in the
feedback
unit,
which
is
mounted
on the
motor stand
and is
connected
to the
pitch position indicator
rod
which
protrudes
from
the
gear housing
flange.
The
control
and
feedback
potentiometer
from
a
balanced
sprit
phase
closed
loop,
feeding
a
high
gain
amplifier
and
phase detecting network.
Movement
of the
control potentiometer
presents
an
error
signal
at the
amplifier
input,
this
signal
is
amplified
and
operates
the
phase detecting network which feeds
a
control signal
to the
solenoid
valve, directing
the oil to the
correct
side
of the
servomotor
cylinder(cross head) which
controls
the
pitch
of the
propeller blades.
The
electrical balance
is
restored
by the
corresponding movement
on the
feedback
potentiometer.
The
system
gives
fine
control
of the
pitch setting,
and any
deviation caused
by
external
forces
is
automatically corrected.
In
addition, this control system provided automatic load control
(ALC)
system which
consists
of
PI
control, load setting
function
and
electric
current signal.
The
electric current signal
is
supplied
from
the CT
located
at
starter
panel.
It has
function that
the
blade angle
is
automatically
reduced
to
protect
the
main motor overload.
The
reducing action
is
achieved when
the
current signal
is
reached
to the
preset
level which
corresponds
to the
rated load
of
motor.
The
action
is
automatically
reset
when
the
load
is
decreased.
5.7
Pitch
to
zero system
During
voyage
of the
vessel, sometimes
the
propeller
is
rotated
by the
tide
( the
seawater
coming
into
the
thruster
tunnel
) and the
pitch
is
moved
out of the
zero
position.
In
this
situation,
the
hydraulic pump automatically will
be
started
and the
pitch
is
kept
in
zero.
When
blade angle
returns
to
zero
position, hydraulic pump
and
solenoid valve will
be
stopped
after
preset
time.
This
mode
is
operated independently
from
normal mode
by
pushing
of
this mode
select
button
on
W/H
control panel.
Other unrelated lamps except followings shall
not be
caused under zero pitch mode.
1)
Ind. lamp
of
zero pitch mode
2)
Ind. lamp
of
blade neutral
3)
Ind. lamp
of
hyd. pump
run
4)
Ind. lamp
of
acting solenoid valve
5)
Alarm lamps
- 5 -