Daewoo DWA-122R Specifications

Browse online or download Specifications for Split-system air conditioners Daewoo DWA-122R. Daewoo DWA-122R Specifications User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Manual de Servicio

Manual de ServicioAcondicionador de Aire Tipo VentanaModelo : DWC-121RDWA-121RDWA-122RDWB-121RDWB-122RDWB-123RDWA-150RDWA-151R

Page 2 - Contents

9Auto Swing(1) When you push this button, in remocon the left/right flap move to the position of keeping the room temperaturecomiortable.(2) The air d

Page 3 - 1. SPECIFICATIONS

103. WIRING DIAGRAM

Page 4 - 2. OPERATION

114. REFRIGERANT CYCLEEvaporatorCapillary tubeBlower fanCondenserPropeller fanAccumulatorCompressorM MOTORCapillary tubeCharge QuantityDWA-121RID1.6Ø

Page 5 - REMOTE CONTROLLER

125. CONTROL BLOCK DIAGRAMRelay 3, 4, 5Auto SwingMoterFan Motor Compressor88 LEDFront PCBFan mode LampTurbo mode LampRemoconSignalReceiverCooling mode

Page 7 - Replacing Batteries

14NO PART NAME SPEC PART CODE Q’TY REMARK1 IC MICOM TMP47P443N 13GSHK64-- 1 U12 IC DRIVE TD62004AP 13GT62004A 1 U33 IC DRIVE TD62783AP 13GT62783A 1 U2

Page 8 - DESCRIPTION OF FUNCTIONS

15NO PART NAME SPEC PART CODE Q’TY REMARK1 LED DISPLAY 88 3103003700 1 DISP2 C-CERA 103Z 50VDC CXCH1H103M 1 C13 RECEIVE MODULE PIC-26043TH2 1PC26043TH

Page 9 - Fan Speed

167. TROUBLE SHOOTING1) Error Code 1(Er)1 Check the connector of room air thermistor. (or connecting wire) 2Check soldering of connecting on control P

Page 10 - Self-Diagnostic Function

17- Check the following at cooling modeCheck the voltage between “POWER ”and “RL1”of Main P.C.B31Check the compressor wiringCheck the Relay(RL1)Check

Page 11 - 3. WIRING DIAGRAM

PCB DRIVING DESCRIPTION

Page 12 - 4. REFRIGERANT CYCLE

CONTENTS1. Specifications ...22. Operation...

Page 13 - 5. CONTROL BLOCK DIAGRAM

19Power Supply(1)DESCRIPTIONDC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Fan MotorDriving Relay, Buzzer D

Page 14 - 6. CIRCUIT DIAGRAM

20Oscillation(2)128 MHzMICOMVDD-10%VSS+10%Fig 2-1DESCRIPTIONOscillatory Frequency drive Micom, it is made up 8MHz resonator oscillatory Freqency.Ocill

Page 15 - Part List

21Room temperature Sensor InputTemperature(°C)No. 15-10 4.060 3.6015 2.7625 2.2040 1.48Voltage (V)Table 3-1Sensor(3)MICOM15R4300C130.01R312.7KVccROOM:

Page 16 - ●Remocon ASS’Y(3108402900)

22DESCRIPTIONSignal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 5, which is gottenfield of Carrier (38KHz) from

Page 17 - 7. TROUBLE SHOOTING

23DESCRIPTIONMICOM Power is supplied 5V at Number 28 using VDD, Number 6 using Analog Reference of A/D Converter.C9, C10 is Ripple filter.Micom Power

Page 18 - Only Compressor Do not Run

24Reset(6)+C111µF/50R15.6K 5V5VRESET ICMICOM370423124.2VHLttPOWERONVcc (+5V)DELAY TIMEFOR POWER ONRESETDESCRIPTIONVoltage less than about 4.2V put

Page 19 - PCB DRIVING DESCRIPTION

25R310K R210K +5VMICOM1327˚F/ ˚CTESTFunction Selecting(7)Table 9-1Selection S/W SHORT OPENFunction˚F / ˚C ˚F ˚CTEST OK NODESCRIPTIONSelecting F

Page 20 - Power Supply(1)

26(1) IC3 (MICOM)(2) U2 (TD62783AP)XOUT1 28 VDDXIN2 27 HOLD (KE0)TESTRESET3 26 R92 (SCK)Display OutR704 25 R91 (SO)Fan Speed(Hi) Display OutR71 (PULSE

Page 21 - Oscillation(2)

27(3) U2(TD62004AP) DARLINGTON ARRAYS(4) U7 (7805CT): VOLTAGE REGULATOR (5VDC)(5) U6 (7812ACT): VOLTAGE REGULATOR (12VDC) IN1 1 16 OUT 1IN2 2 15

Page 22 - DESCRIPTION

289. DISASSEMBLY INSTRUCTIONS1 Before service of 1. Stop the unit, remove the power cord from the receptacles.any part. 2. Move the unit to the safe l

Page 23

21. SPECIFICATIONSITEMMODELDWC-121R DWA-121R DWA-122R DWB-121R DWB-122R DWB-123R DWA-150R DWA-151RFunctionPower sourceAC 115V, 60HzCooling CapacityBtu

Page 24

29• HOW TO REMOVE THE FRONT GRILLE1. Remove the Air Filter from the front grill by pulling to right.2. Remove two screw tapping from front grille.3. P

Page 25

3010. EXPLODED DIAGRAM AND PARTS LIST DWA-121R, DWA-122R, DWB-121R, DWB-122R, DWB-123R, DWC-121R, DWA-150R, DWA-151R PARTS LISTNO CODE COMPONENTS Q&ap

Page 26

31NO CODE COMPONENTS Q'TY SPECIFICATION REMARK19 3106800300 ASS'Y CONDENSOR 1 3R2C, Ø719-1 3108504300 SEAL COND TOP 1 F-US20 3101202800 CLIP

Page 27 - TMP47C443N

32NO CODE COMPONENTS Q'TY SPECIFICATION REMARK44 3109505110 CAPACITOR 1 5/35µF,400VAC DWB-121R,123R(ONLY)3109507700 CAPACITOR 1 5/35µF,400VAC DWB

Page 28

DWA-121R, DWA-122R, DWB-121R, DWB-122R, DWB-123R, DWC-121R, DWA-150R55

Page 29 - 9. DISASSEMBLY INSTRUCTIONS

A-151R EXPLODED DIAGRAM5354

Page 30

S/M NO.: DWC121R030DAEWOO ELECTRONICS CO., LTD.686, AHYEON-DONG MAPO-GU SEOUL, KOREAC.P.O. BOX 8003 SEOUL, KOREATELEX: DWELEC K28177-8CABLE: “DAEWOOEL

Page 31 - DWA-150R, DWA-151R PARTS LIST

31PARTS OF NAME AND FUNCTION2. OPERATION● DW*-121R/DW*-122R/DWB-123R/DWA-150R/DWA-151R (NOTE:* ➔ A or B or C)NO PART NAME1 AIR FILTER2 GRILLE FRONT3 C

Page 32

42REMOTE CONTROLLERREMOCON SIGNAL TRANSMITTERTIMER/CANCEL• Everytime you push this button,timer is set as follow.(1Hr→2Hr→3Hr→4Hr→5Hr→6Hr→8Hr→10Hr→12H

Page 33 - ✻ → A or B or C

53REMOTE CONTROLLER DISPLAYRoom Air-conditionerFANTURBOCOOLINGROOM TEMPTEMPDESIRED TEMPTIMERSENSORMODE POWERFANSPEEDAUTOSWING88TEMP./TIMER DISPLAY• It

Page 34

Replacing Batteries6Remove the COVER fromthe back of the remotecontroller.• Slide the coveraccording to the arrowdirectionInsert two battaries. • Be s

Page 35 - A-151R EXPLODED DIAGRAM

7If you set time in OFF-Timer Mode, the unit will stop at the set time.If you set time in ON-Timer Mode, the unit will run at the set time.(1) Range o

Page 36 - DAEWOO ELECTRONICS CO., LTD

8(1) When you are going to sleep, select sleep button in remocon and the unit controls the room to the desiredtemperature. (The unit will not operate

Comments to this Manuals