Manual de servicioSplit Acondicionador de AireModelo : DSA-099LDSA-129LDSA-189L aviso:En este manual,algunas part
Stop operation of the air conditioner and remove the power cord before repairing the unitIndoor unit DISASSEMBLY AND REASSEMBLYNo Parts Procedure Rema
DISASSEMBLY AND REASSEMBLY10104.Separate the electrical box from the indoor unit. 1.Loosen the earth screw in evaporator.2.Loosen the sul
DISASSEMBLY AND REASSEMBLY3.Separate the evaporator from the indoor unit.4Evaporator2.Separete the ass’y tray drain from the body.1.Push the left
DISASSEMBLY AND REASSEMBLY1 Cabinet 1.Turn off the unit and remove the power cable.2.Remove the upper cabinet, the front cabinet and bac
1 Cabinet 1.Turn off the unit and remove the power cable.2.Remove the upper cabinet, the front cabinet and back cabinet.2.separate t
DISASSEMBLY AND REASSEMBLY2.Loosen the nut flange on compressor.3.Separate the connector.4.Separate the ass' y control out from the ou
If problems can not be corrected after doing below items, please stop the air conditioner, contact our air conditioner specially eng-aged service c
Indoor unit fan stopsfor about 10 minutes during heating.It is defrosting of the outdoor unit coil.It should complete this process in about 10 minutes
Exploded Views and Parts ListIndoor unit1717DSA-099L DSA-129L
Exploded Views and Parts ListIndoor unit1818DSA-099L DSA-129LNo. Part Name Quantity Item Code 1. Righ t air filter 1 KFR25G.1.1.2-5(A1-GB40) 2
CONTENTSPP11Contents...1Service and Maintenance ...
Exploded Views and Parts ListOutdoor unit1919DSA-099L DSA-129L
Exploded Views and Parts ListOutdoor unit2020DSA-099L DSA-129LNo. Part Name Quantity Item Code 1. Air outlet grille 1 KFR20W.1.1-2 2 Front pan
Exploded Views and Parts ListIndoor unit2121DSA-189L
Exploded Views and Parts ListIndoor unit2222DSA-189LNo. Part Name Quantity Item Code 1. Connecting board of mounting plate 1 KFR36G.9-2(D9-130
Exploded Views and Parts ListOutdoor unit27115161826201924232221257891011121314176543212323DSA-189L
Exploded Views and Parts ListOutdoor unit2424DSA-189LNo. Part Name Quantity Item Code 1. Air outlet grille 1 KFR35W.1.2-3(G1-1) 2 Fan screw n
Remote controller11223344556677881010Quantity11111111114Ass’y PCB remoconScrewcase upConduct rubberInlay LCDLCD screenSpring batteryNameBack bodyNumbe
Wiring diagram 2626PIPE THERMISTORROOM THERMISTOR
DRIVEA/O CONVERTERMAIL PCBLED PCBREMOTE CONTROLLERAC POWER INPUTOutdoor Fan Motor4.75V12VRemote and EmergencyMode Slector Sleep lampTimer lampTempera
113322113322Air Conditioner no use for a long time.Start fan only for 3-4 hours to comple-tely dry the inside of the indoor unit. Set COOL mode or
3311144332211443322Filters should be cleaned once every two weeks.Take out filters.Clean filters with a vacuum cleaner or by typing them gently. (
CONTROLS SPECIFICATION1122ABBREVIATIONTs: Setting TemperatureTr: Room TemperatureTi: Indoor defrost sensor temperatureTo: Outdoor defrost sensor tempe
Outdoor de-iceAfter 40 minutes of continuous heating operation, if To -4 , the outdoor de-ice operation is activated. Compressor is turned off. I
TIMERTimer off can only be set when the system is operating.Timer on can only be set when the system is off.The maximum set time is 12 hours.Changing
MANUAL SWING (STEPPING MOTOR)If the indoor fan is operating, the louver will swing or can be stopped at a preferred location in any mode. The louver
MANUAL OPERATION BUTTON33OPERATION OF CONTROL PANEL ON INDOOR UNITEvery press of this button will turn the system on or off.SYSTEM LED LIGHT