7) When “ ” comes on display.
CHECK METHOD
if clock does not keep exact time, you must check. Diode 1, transistor Q2.
POINT WAVEFORM
A
B
C
T: 20ms (60 Hz)
6
7
8
C7
473
D1
1N4148
1N4004
D7
1N4004
D8
R17
4.7K
R16
4.7K
C
Q1
C3198
C5
473
R13
4.7K
C5
102
R15
4.7K
C1
V1
45 INT1
B
A
+5V
0V
T
T=20ms (50Hz)
6) When the door is opened during operation, the count down timer does not stop.
CHECK METHOD
V1
R25
4.7K
R24
100K
B
C12
104
C13
104
47
R23
330
R28
4.7K
R22
4.7K
CN2
35313-0210
D.O.M
COM
NO
1
2
A
POINT
AB
STAGE
DOOR OPENED OPEN +5VDC
DOOP CLOSED CLOSED GND
NOTE :
Check the state of the secondary interlock switch.