OPERATION AND FUCTIONS
Sensors
Circuit Diagram
Fnction of Each Sensor
[ F-sensor ]
1) It senses the temperature of freezer compartment and controls Comp., F-fan ON / OFF.
2) How it works ;
Working Point Low ON Mid OFF High OFF
Working Temp. -11.0 -20.0 - 26.0
Resistance 14.74k 22.33k 30.92k
Sensing Voltage 3.50 V 3.00 V 2.14 V
[ D-sensor ]
It senses return point of defrosting heater.
Working Point Return point of defrosting heater
Working Temp. 10
Resistance
19.53k
Sensing Voltage
3.1 V
[ R-sensor ]
1) It senses the temperature of refrigerator compartment and controls R-fan ON / OFF.
2) How it works ;
Working Point Low ON Mid OFF High OFF
Working Temp. 2.65 0.3 -1.7
Resistance 26.88k 29.34k 32.00k
Sensing Voltage 2.90V 2.81V 2.74V
C C C
C
C C C