35
7. Case of no stopping of the count down timer
When the door is opened during operation, the count down timer does not stop.
- Check method
POINT
STATE
DOOR OPEN
DOOR CLOSED
A
OPEN
CLOSE
B
+5V DC
GND
CHECK NO METHOD REMEDY
1 Check the stage(ON,OFF) of the door open Replace door open monitor swith.
monitor switch by resistance measurement.
Comments to this Manuals